Hospital ICU Medical Anesthesia Machine

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Anesthesia Machine
Still deciding? Get samples of US$ 4000/Piece
Request Sample
Manufacturer/Factory, Group Corporation
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (12)
  • Hospital ICU Medical Anesthesia Machine
  • Hospital ICU Medical Anesthesia Machine
  • Hospital ICU Medical Anesthesia Machine
  • Hospital ICU Medical Anesthesia Machine
  • Hospital ICU Medical Anesthesia Machine
  • Hospital ICU Medical Anesthesia Machine
Find Similar Products

Basic Info.

Group
Adult and Child
Transport Package
Suit for The Medical Equipment Packaging
Trademark
YALIYA
Origin
China
Production Capacity
1000units/Month

Product Description

Hospital ICU Medical Anesthesia MachineHospital ICU Medical Anesthesia MachineHospital ICU Medical Anesthesia MachineHospital ICU Medical Anesthesia MachineHospital ICU Medical Anesthesia MachineHospital ICU Medical Anesthesia MachineHospital ICU Medical Anesthesia MachineHospital ICU Medical Anesthesia MachineHospital ICU Medical Anesthesia MachineACM602 Anesthesia machine

Main characters
Application Adult & Child
Driven mode pneumatically driven and electrically controlled
Ventilation modes IPPV, manual
Respiratory rate 6bpm~40bpm
Tidal volume 0,50ml~1200ml
I/E ratio 1:1, 2:3, 1:2, 1:3
Display high-luminance LED display
Ventilator compliance ≤4mL/100Pa
Safety pressure in the airway system of ventilator ≤6kPa
Monitoring parameters
Tidal volume, Respiratory rate
Alarms
Upper airway pressure limit, Lower airway pressure limit, Power failure, Silence time for alarm, Alarm
for oxygen supply failure
ANESTHESIAMACHINE
Followmeter
O2
0.05~10L/min
N2
O 0.05~10L/min
ORC device The proportion between O2 and N2
O can be continuously
adjustable to assure the O2
concentration above21%
Safety performance
Alarm for oxygen failure, Overflow valve, Safety valve, N2O cut-off with oxygen failure

Standard
One vaporizer carton:60*60*150cm 60kg 80kg


ACM608B Anesthesia machine

Application Adult & Child
Driven mode Pneumatically driven and electrically controlled, time switch, volume
constant
Ventilation modes IPPV, SIPPV, SIMV, CPAP, SIGH, MANUAL
Respiratory rate 4bpm ~ 99bpm
Accumulative total respiratory rate 0bpm ~ 99bpm
Tidal volume 0,50ml ~ 1600ml
I/E ratio 1:8,1:7.5,1:7,1:6.5,1:6,1:5.5,1:5,1:4.5,1:4,1:3.5,1:3,1:2.5,
1:2,1:1.5,1:1, 1:0.7,1:0.5,1:0.3,1:02,1:0.1
Triggering sensitivity 0 kPa ~ 2.0kPa(the same function as PEEP) Display Color
TFT+high-luminance LED display Waveform Airway-pressure waveform displaying
Monitoring parameters
Tidal volume, Minute volume, total respiratory rate, Real time airway monitoring, Ppeak, PEEP, Average pressure,
Trend diagram
Alarms
Airway pressure, Tidal volume, Triggering sensitivity, Minute volume, Oxygen concentration, Respiratory rate,
Apneaventilation, Alarm for oxygen supply failure, Power failure, Safety pressure of the airway system
ANESTHESIA MACHINE Flowmeter
O2
(two tubes) 0.05~1L/min; 1.0~10L/min
N2
O (two tubes) 0.05~1L/min; 1.0~10L/min
Air (two tubes) 0.05~1L/min;1.0~10L/min
ORC device The proportion between O2 and N2
O can be
Continuously adjustable to assure the O2
concentrationabove21%

Standard Two vaporizers       
carton1:91*83*157cm 100kg 110kg carton2:42*43*57cm 10kg 15kg

ACM619(5.7'screen ) Anesthesia machine

ANESTHESIA MACHINE
Supply gas pressure: 280kPa-600kPa;
evaporator concentration 0.2%~5%;
Flowmeter adjust range 0.05L~10L;
Oxygen concentration ≥21%; O2 flush 25L/min~75L/min
Gas pressure alarm (electromotion) 0.185~0.22MPa
Power <50VA
Machine noise £65db
Input power supply AC 110/220V input
Output power supply DC 24V output,tolerance±1%
Power supply Interface RS485
Anti-jamming requirement it can resist the power conduct and radiation of other
equipments
Language Chinese, English
Followmeter
O2
(two tubes) 0.05~1L/min;1.0~10L/min
N2
O (two tubes) 0.05~1L/min;1.0~10L/min
Air (two tubes) 0.05~1L/min;1.0~10L/min
ORC device The proportion between O2 and N2
O can be continuously adjustable to assure the O2
concentration
above21%
ANESTHESIA VENTILATOR The main
characters
Application Adult & Child
Driven mode Pneumatically driven and electrically controlled, time switch
Ventilation modes VC-IPPV,VC-SIPPV,VC-SIGH,VC-SIMV,PC-IPPV,
PC-SIMV,PC-SIPPV,VC-PSV,PC-PSV, PR-IPPV,PR-SIPPV,
PR-SIMV,PR-PSV,Manual
Respiratory rate 1bpm~100bpm, tolerance ±15%
Tidal volume working range 20mL~1600mL ,continuously adjustable.
I/E ratio 1:0.3~1:8
Triggering sensitivity 0.0kPa~2.0 kPa,tolerance±0.1kPa
Display LED display
Waveform Double waveforms displaying for pressure-time and flow-time
(optional: volume-time, CO2-time, pressure volume loop, flow
volume loop)
The safety pressure of gas circle system less than10kPa±15%;
Inspiratory platform 0-60% inspiratory time
Inspiratory pressure 0.3kPa~6.0kPa,tolerance±0.1kPa;
Inspiratory rise time 0.02s~2.00s
Supply pressure 0.3kPa~6.0 kPa,tolerance±0.1kPa
Triggering flowrate OFF,0.1LPM~20LPM,tolerance±0.5LPM
PEEP OFF,0.3kPa~3.0 kPa,tolerance±0.1kPa
PS switch flowrate 1%~60% maximal flow
PS Inspiratory rise time 0.02s~2.00s
triggering window 20%~60%
Pressure Limit 0.9kPa~7.9 kPa
Monitoring parameters
Respiratory rate, I/E ratio, breath holding time, Tidal volume, Minute volume, Ppeak, Average Pressure, minimum
pressure, PEEP, FIO2 concentration, Optional (FICO2 concentration, ETCO2 concentration, BIS), compliance
Alarms
Airway pressure, Tidal volume, Minute volume, Oxygen concentration, Power failure, Apnea, Flow sensor failure,
Respiratory rate, Flow sensor failure, Optional(ETCO2 concentration,FICO2 concentration), Lower gas pressure,
sustained pressure, complete pipeline, PEEP, Silence time for alarm:≤120s.
Other function
Altitude compensation, O2 compensation, N2O compensation, big screen display, alarm volume adjustment, Start self-test,
compliance compensation, leakage compensation

Standard (two vaporizeres)               
Carton 1:91*83*157cm 100kg 110kg carton2:42*43*57cm 10kg 15kg

ACM619F (10.4' screen) 
ANESTHESIA MACHINE
Supply gas pressure: 280kPa-600kPa;
evaporator concentration 0.2%~5%;
Flowmeter adjust range 0.05L~10L;
Oxygen concentration ≥21%; O2 flush 25L/min~75L/min
Gas pressure alarm (electromotion) 0.185~0.22MPa
Power <50VA
Machine noise £65db
Input power supply AC 110/220V input
Output power supply DC 24V output,tolerance±1%
Power supply Interface RS485
Anti-jamming requirement it can resist the power conduct and radiation of other
equipments
Language Chinese, English
Followmeter
O2
(two tubes) 0.05~1L/min;1.0~10L/min
N2
O (two tubes) 0.05~1L/min;1.0~10L/min
Air (two tubes) 0.05~1L/min;1.0~10L/min
ORC device The proportion between O2 and N2
O can be continuously adjustable to assure the O2
concentration
above21%
ANESTHESIA VENTILATOR The main
characters
Application Adult & Child
Driven mode Pneumatically driven and electrically controlled, time switch
Ventilation modes VC-IPPV,VC-SIPPV,VC-SIGH,VC-SIMV,PC-IPPV,
PC-SIMV,PC-SIPPV,VC-PSV,PC-PSV, PR-IPPV,PR-SIPPV,
PR-SIMV,PR-PSV,Manual
Respiratory rate 1bpm~100bpm, tolerance ±15%
Tidal volume working range 20mL~1600mL ,continuously adjustable.
I/E ratio 1:0.3~1:8
Triggering sensitivity 0.0kPa~2.0 kPa,tolerance±0.1kPa
Display LED display
Waveform Double waveforms displaying for pressure-time and flow-time
(optional: volume-time, CO2-time, pressure volume loop, flow
volume loop)
The safety pressure of gas circle system less than10kPa±15%;
Inspiratory platform 0-60% inspiratory time
Inspiratory pressure 0.3kPa~6.0kPa,tolerance±0.1kPa;
Inspiratory rise time 0.02s~2.00s
Supply pressure 0.3kPa~6.0 kPa,tolerance±0.1kPa
Triggering flowrate OFF,0.1LPM~20LPM,tolerance±0.5LPM
PEEP OFF,0.3kPa~3.0 kPa,tolerance±0.1kPa
PS switch flowrate 1%~60% maximal flow
PS Inspiratory rise time 0.02s~2.00s
triggering window 20%~60%

Standard
(two vaporizeres)               
carton1:91*83*157cm 100kg 110kg carton2:42*43*57cm 10kg 15kg

ACM639(10" screen, manual flowmeter) Anesthesia machine

10'' high-luminance large screen displaying
intelligent safe self-test and alarm function
real-time monitoring pressure, flow, volume
waveform and breathing loops
humanized design and clear functional zone
make it easy to operate
 fully functional host machine
system
integrated respiratory circuit, safe and
reliable.
powerful battery back-up power supply system
large double drawer design to meet clinical requirement fully.
extensible modular design, upgrade easily.

Standard (two vaporizeres)         
carton:103*95*150 130kg 150kg

ACM659 (12' touch screen)

with ICU quality multifunction
anesthesia machine
15'' high-luminance large screen displaying
intelligentized safe self-test and alarm function
real-time monitoring pressure, flow, volume
waveform and breathing loops
humanized design and clear functional zone
make it easy to operate
electrical flowmeter can realize gas automatic
monitoring and switch function.
Innovation respiratory system design
the whole respiratory system built-in the machine body, easy to dissemble.
 efficient integrated gas distribution system
 low respiratory circuit compliance to meet the low-flow requirements

Standard (two vaporizeres)             
carton:100*90*165cm 190kg 200kg



For more information please visit our website:

https://yaliya.en.made-in-china.com


Contact person: Mr Kevin Chen

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More