Acm608b Anesthesia Machine
Product Details
Classification:
Physiological Functions of Diagnosis and Monitoring Equipment
Main characters Application Adult & Child Driven mode pneumatically driven and electrically controlled Ventilation modes IPPV, manual Respiratory rate 6bpm~40bpm Tidal volume 0,50ml~1200ml I/E ratio 1:1, 2:3, 1:2, 1:3 Display high-luminance LED display Ventilator compliance ≤4mL/100Pa Safety pressure in the airway system of ventilator ≤6kPa Monitoring parameters Tidal volume, Respiratory rate Alarms Upper airway pressure limit, Lower airway pressure limit, Power failure, Silence time for alarm, Alarm for oxygen supply failure ANESTHESIAMACHINE Followmeter O2 0.05~10L/min N2 O 0.05~10L/min ORC device The proportion between O2 and N2 O can be continuously adjustable to assure the O2 concentration above21% Safety performance Alarm for oxygen failure, Overflow valve, Safety valve, N2O cut-off with oxygen failure
Standard One vaporizer carton:60*60*150cm 60kg 80kg
ACM608B Anesthesia machine
Application Adult & Child Driven mode Pneumatically driven and electrically controlled, time switch, volume constant Ventilation modes IPPV, SIPPV, SIMV, CPAP, SIGH, MANUAL Respiratory rate 4bpm ~ 99bpm Accumulative total respiratory rate 0bpm ~ 99bpm Tidal volume 0,50ml ~ 1600ml I/E ratio 1:8,1:7.5,1:7,1:6.5,1:6,1:5.5,1:5,1:4.5,1:4,1:3.5,1:3,1:2.5, 1:2,1:1.5,1:1, 1:0.7,1:0.5,1:0.3,1:02,1:0.1 Triggering sensitivity 0 kPa ~ 2.0kPa(the same function as PEEP) Display Color TFT+high-luminance LED display Waveform Airway-pressure waveform displaying Monitoring parameters Tidal volume, Minute volume, total respiratory rate, Real time airway monitoring, Ppeak, PEEP, Average pressure, Trend diagram Alarms Airway pressure, Tidal volume, Triggering sensitivity, Minute volume, Oxygen concentration, Respiratory rate, Apneaventilation, Alarm for oxygen supply failure, Power failure, Safety pressure of the airway system ANESTHESIA MACHINE Flowmeter O2 (two tubes) 0.05~1L/min; 1.0~10L/min N2 O (two tubes) 0.05~1L/min; 1.0~10L/min Air (two tubes) 0.05~1L/min;1.0~10L/min ORC device The proportion between O2 and N2 O can be Continuously adjustable to assure the O2 concentrationabove21%
ANESTHESIA MACHINE Supply gas pressure: 280kPa-600kPa; evaporator concentration 0.2%~5%; Flowmeter adjust range 0.05L~10L; Oxygen concentration ≥21%; O2 flush 25L/min~75L/min Gas pressure alarm (electromotion) 0.185~0.22MPa Power <50VA Machine noise £65db Input power supply AC 110/220V input Output power supply DC 24V output,tolerance±1% Power supply Interface RS485 Anti-jamming requirement it can resist the power conduct and radiation of other equipments Language Chinese, English Followmeter O2 (two tubes) 0.05~1L/min;1.0~10L/min N2 O (two tubes) 0.05~1L/min;1.0~10L/min Air (two tubes) 0.05~1L/min;1.0~10L/min ORC device The proportion between O2 and N2 O can be continuously adjustable to assure the O2 concentration above21% ANESTHESIA VENTILATOR The main characters Application Adult & Child Driven mode Pneumatically driven and electrically controlled, time switch Ventilation modes VC-IPPV,VC-SIPPV,VC-SIGH,VC-SIMV,PC-IPPV, PC-SIMV,PC-SIPPV,VC-PSV,PC-PSV, PR-IPPV,PR-SIPPV, PR-SIMV,PR-PSV,Manual Respiratory rate 1bpm~100bpm, tolerance ±15% Tidal volume working range 20mL~1600mL ,continuously adjustable. I/E ratio 1:0.3~1:8 Triggering sensitivity 0.0kPa~2.0 kPa,tolerance±0.1kPa Display LED display Waveform Double waveforms displaying for pressure-time and flow-time (optional: volume-time, CO2-time, pressure volume loop, flow volume loop) The safety pressure of gas circle system less than10kPa±15%; Inspiratory platform 0-60% inspiratory time Inspiratory pressure 0.3kPa~6.0kPa,tolerance±0.1kPa; Inspiratory rise time 0.02s~2.00s Supply pressure 0.3kPa~6.0 kPa,tolerance±0.1kPa Triggering flowrate OFF,0.1LPM~20LPM,tolerance±0.5LPM PEEP OFF,0.3kPa~3.0 kPa,tolerance±0.1kPa PS switch flowrate 1%~60% maximal flow PS Inspiratory rise time 0.02s~2.00s triggering window 20%~60% Pressure Limit 0.9kPa~7.9 kPa Monitoring parameters Respiratory rate, I/E ratio, breath holding time, Tidal volume, Minute volume, Ppeak, Average Pressure, minimum pressure, PEEP, FIO2 concentration, Optional (FICO2 concentration, ETCO2 concentration, BIS), compliance Alarms Airway pressure, Tidal volume, Minute volume, Oxygen concentration, Power failure, Apnea, Flow sensor failure, Respiratory rate, Flow sensor failure, Optional(ETCO2 concentration,FICO2 concentration), Lower gas pressure, sustained pressure, complete pipeline, PEEP, Silence time for alarm:≤120s. Other function Altitude compensation, O2 compensation, N2O compensation, big screen display, alarm volume adjustment, Start self-test, compliance compensation, leakage compensation
Standard (two vaporizeres) Carton1:91*83*157cm 100kg 110kg carton2:42*43*57cm 10kg 15kg
ACM619F (10.4' screen) ANESTHESIA MACHINE Supply gas pressure: 280kPa-600kPa; evaporator concentration 0.2%~5%; Flowmeter adjust range 0.05L~10L; Oxygen concentration ≥21%; O2 flush 25L/min~75L/min Gas pressure alarm (electromotion) 0.185~0.22MPa Power <50VA Machine noise £65db Input power supply AC 110/220V input Output power supply DC 24V output,tolerance±1% Power supply Interface RS485 Anti-jamming requirement it can resist the power conduct and radiation of other equipments Language Chinese, English Followmeter O2 (two tubes) 0.05~1L/min;1.0~10L/min N2 O (two tubes) 0.05~1L/min;1.0~10L/min Air (two tubes) 0.05~1L/min;1.0~10L/min ORC device The proportion between O2 and N2 O can be continuously adjustable to assure the O2 concentration above21% ANESTHESIA VENTILATOR The main characters Application Adult & Child Driven mode Pneumatically driven and electrically controlled, time switch Ventilation modes VC-IPPV,VC-SIPPV,VC-SIGH,VC-SIMV,PC-IPPV, PC-SIMV,PC-SIPPV,VC-PSV,PC-PSV, PR-IPPV,PR-SIPPV, PR-SIMV,PR-PSV,Manual Respiratory rate 1bpm~100bpm, tolerance ±15% Tidal volume working range 20mL~1600mL ,continuously adjustable. I/E ratio 1:0.3~1:8 Triggering sensitivity 0.0kPa~2.0 kPa,tolerance±0.1kPa Display LED display Waveform Double waveforms displaying for pressure-time and flow-time (optional: volume-time, CO2-time, pressure volume loop, flow volume loop) The safety pressure of gas circle system less than10kPa±15%; Inspiratory platform 0-60% inspiratory time Inspiratory pressure 0.3kPa~6.0kPa,tolerance±0.1kPa; Inspiratory rise time 0.02s~2.00s Supply pressure 0.3kPa~6.0 kPa,tolerance±0.1kPa Triggering flowrate OFF,0.1LPM~20LPM,tolerance±0.5LPM PEEP OFF,0.3kPa~3.0 kPa,tolerance±0.1kPa PS switch flowrate 1%~60% maximal flow PS Inspiratory rise time 0.02s~2.00s triggering window 20%~60%
Standard (two vaporizeres) carton1:91*83*157cm 100kg 110kg carton2:42*43*57cm 10kg 15kg
10'' high-luminance large screen displaying intelligent safe self-test and alarm function real-time monitoring pressure, flow, volume waveform and breathing loops humanized design and clear functional zone make it easy to operate fully functional host machine system integrated respiratory circuit, safe and reliable. powerful battery back-up power supply system large double drawer design to meet clinical requirement fully. extensible modular design, upgrade easily.
Standard (two vaporizeres) carton:103*95*150 130kg 150kg
ACM659 (12' touch screen)
with ICU quality multifunction anesthesia machine 15'' high-luminance large screen displaying intelligentized safe self-test and alarm function real-time monitoring pressure, flow, volume waveform and breathing loops humanized design and clear functional zone make it easy to operate electrical flowmeter can realize gas automatic monitoring and switch function. Innovation respiratory system design the whole respiratory system built-in the machine body, easy to dissemble. efficient integrated gas distribution system low respiratory circuit compliance to meet the low-flow requirements
Standard (two vaporizeres) carton:100*90*165cm 190kg 200kg